
02 / High-density colocation
Your hardware. A considered home.
Bring your GPU hardware. We assess the power, cooling, networking, and operating envelope around it, starting with engineering fit.
The application
Fit comes first.
Owned hardware deserves more than a generic rack allocation. Every interface is part of the intake.
- 01
Rack and node
Map node dimensions, rack geometry, and maintenance access against the deployment envelope.
- 02
Power and cooling
Review the operating envelope and cooling interfaces, including how your nodes map to direct-to-chip liquid cooling.
- 03
Network and storage
Confirm the topology, fabric configuration, and storage requirements before hardware moves.

Reference specification
A reference. Not an assumption.
Pod 32 describes the reference infrastructure envelope. Your engineering review determines the configuration and whether your hardware fits.
Explore the technology| Compute | 32 Supermicro HGX B300 nodes |
|---|---|
| GPUs | 256 NVIDIA B300 |
| Racks | 4 |
| Operating load | 645 kW |
| System memory | 128 TB |
| Storage | 983 TB raw NVMe per module |
| Fabric | Rail-optimized 400G Ethernet |
| Fabric throughput | Configurable 3.2 or 6.4 Tbps per node |
| Cooling | Direct-to-chip liquid, redundant CDUs |
| Site water | No site water requirement |
| Tenancy | Single-tenant bare metal |
Engineering and operations
Clear ownership. Documented handoff.
Managed infrastructure
Pacific operates remotely with contracted regional field service. Hardware, software, maintenance access, and exit responsibilities are defined during discovery.
Evidence at acceptance
Factory, site, and integration checks follow a 24-stage test program. Measured NCCL criteria apply where the network fabric is in scope.
Controlled changes
Configuration changes after handoff follow acceptance control, with evidence. Service responsibilities and terms are defined in the contract.
Start a conversation
A little context. A useful call.
Three short questions, then choose a time. No project names or sensitive details needed.
Question 1 of 3
Your role
Only broad answer categories are recorded. Keep sensitive project details for the conversation.
Book without the questions Open Cal.com in a new tabFurther detail
Before we talk.
What hardware fits?
An engineering intake maps your rack and node dimensions, power envelope, cooling interfaces, network topology, and service access against the infrastructure. Fit is confirmed by that review, not assumed.
Who operates what?
Pacific runs the infrastructure through remote operations and contracted regional field service. Responsibility for your hardware, software stack, and maintenance access is defined explicitly during discovery.
Is liquid cooling required?
The reference environment is direct-to-chip liquid cooling with redundant CDUs and no site water requirement. The fit review determines how your hardware's cooling profile maps onto it.
How is acceptance handled?
Handoff follows factory, site, and integration evidence gates, including measured NCCL fabric criteria where the network fabric is in scope for your deployment.
What are the commercial terms?
Terms are discussed privately on a qualified colocation call. Pacific does not publish rates.
